抽象的

A Reverse Phase High Performance Liquid Chromatography Method For Simultaneous Estimation Of Paracetamol And Valdecoxib In Pharmaceutical Formulation

S.N.Meyyanathan, R.Gopinath, S.Rajan, N.Krishnaveni, B.Suresh


A simple, selective, rapid, precise and economical reverse phase HPLC method has been developed for the simultaneous estimation of paracetamol and valdecoxib from tablets. The method was carried out on a Phenomenex Gemini C18 (25 cm x 4.6 mm i.d., 5μ) column with a mobile phase consisting of acetonitrile: 20 mM octane sulphonic acid buffer (adjusted to pH 3.0 using orthophosphoric acid) (50:50 v/v) at a flow rate of 1.0 ml/min. Detection was carried out at 240 nm. Bromhexine was used as an internal standard. The retention time of paracetamol, bromhexine and valdecoxib was 2.97, 5.85 and 8.05 min, respectively. The developed method was validated in terms of accuracy, precision, linearity, limit of detection, limit of quantitation and solution stability. The proposed method can be used for the estimation of these drugs in combined dosage forms.


索引于

  • 中国社会科学院
  • 谷歌学术
  • 打开 J 门
  • 中国知网(CNKI)
  • 引用因子
  • 宇宙IF
  • 电子期刊图书馆
  • 研究期刊索引目录 (DRJI)
  • 秘密搜索引擎实验室
  • ICMJE

查看更多

期刊国际标准号

期刊 h 指数

Flyer