抽象的

Atorvastatin analysis by fully validatedHPLC assay in human plasma

Reem Saleh Alswayeh, Muhammad M.Hammami


Asimple, sensitive high-performance liquid chromatography (HPLC) assay for atorvastatin measurement in human plasma was fully validated, and atorvastatin stability was studied. After one-step extraction of 1ml plasma with 5.0ml of ethyl acetate and reconstitution in mobile phase, glipizide (internal standard, IS) and atorvastatin eluted at 4.6 and 8.7 minutes, respectively, on anAtlantis C18, 5msteel at roomtemperature (RT), and were detected using a Water 2690 dual absorbance detector set at 247nm. The mobile phase, 0.05 M dibasic sodium phosphate buffer (pH = 4.0) and acetonitrile (50:50, v:v), was delivered at 1.0ml/min. Calibration curves were linear in the range 0.02-1.0g/ml, and intra- and inter-run coefficients of variation were  12 % and 13.1 %, respectively. Extraction recovery and intra- and inter-run biaswere  81%(mean 91%), 14%, and  10%, respectively. Atorvastatinwas stable in plasma for 24 hours atRT ( 95%), 6 weeks at -20C ( 85%), and after 3 cycles of freeze at -20C and thaw at RT ( 90%). In extracted samples, atorvastain was stable for 24 hours at RT ( 96%) and 48 hours at -20C ( 96%). Atorvastatin (1 mg/ml) in water was stable for 48 hours at RT (88%) and 6 weeks at -20C (112%).


免责声明: 此摘要通过人工智能工具翻译,尚未经过审核或验证

索引于

  • 中国社会科学院
  • 谷歌学术
  • 打开 J 门
  • 中国知网(CNKI)
  • 引用因子
  • 宇宙IF
  • 电子期刊图书馆
  • 研究期刊索引目录 (DRJI)
  • 秘密搜索引擎实验室
  • ICMJE

查看更多

期刊国际标准号

期刊 h 指数

Flyer