抽象的

Development and validation of a rapid RP-HPLC method for the determination of tadalafil in bulk and in formulation

K.Anandakumar, K.Varadharajan, D.Jothieswari, R.Subathrai, G.Sivanseyal, J.Suresh


Asimple, selective, linear, precise and accurate RP-HPLC method was developed and validated for assay of Tadalafil in bulk and in tablet dosage forms. Isocratic elution at a flow rate of 0.9 ml/ min was employed on a Phenomenax Luna C18 column (1504.6 mm; 5) at ambient temperature. The mobile phase consisted of acetonitrile and water (50:50% v/v). The detection wavelength was 295nm and 25l of sample was injected. Lamotrigine was used as an internal standard (IS). The retention times for TDF and IS were 4.12 and 2.29 min, respectively. Themethod obeys Beer’s law in the concentration range of 1-5g/ml. The method was successfully applied to commercial pharmaceuticals and validated as per standard analytical procedures. The proposed method could be applicable for routine analysis of TDF in bulk and in formulations.


免责声明: 此摘要通过人工智能工具翻译,尚未经过审核或验证

索引于

  • 中国社会科学院
  • 谷歌学术
  • 打开 J 门
  • 中国知网(CNKI)
  • 引用因子
  • 宇宙IF
  • 电子期刊图书馆
  • 研究期刊索引目录 (DRJI)
  • 秘密搜索引擎实验室
  • ICMJE

查看更多

期刊国际标准号

期刊 h 指数

Flyer