抽象的

Development and Validation of RP HPLC Method for the Estimation of Cefetamet in Bulk and Tablet Dosage Form

N. Prudhvi, K. P. Channabasavaraj, Y. N. Manohara, A. L. Rao and D. B. Raju


A simple, rapid, sensitive and precise High Performance Liquid Chromatography (HPLC) method has been developed for the estimation of cefetamet in bulk and tablet dosage form. In this method, RP-C18 column (150 mm x 4.6 mm I.D., 5 7m particle size) with mobile phase consisting of acetonitrile, methanol and phosphate buffer (pH 3.60) in the ratio of 50 : 20 : 30 v/v/v in isocratic mode was used. The detection wavelength is 236 nm and the flow rate was 0.8 mL/min. In the range of 5-25 7g/mL, the linearity of cefetamet shows a correlation coefficient of 0.9995. The proposed method was validated by determining sensitivity, accuracy, precision and system suitability parameters. The method is simple, fast, accurate and precise and hence, it can be applied for routine analysis of cefetamet in bulk drug and its tablet dosage form.


免责声明: 此摘要通过人工智能工具翻译,尚未经过审核或验证

索引于

  • 中国社会科学院
  • 谷歌学术
  • 打开 J 门
  • 中国知网(CNKI)
  • 引用因子
  • 宇宙IF
  • 米亚尔
  • 秘密搜索引擎实验室
  • 欧洲酒吧
  • 巴塞罗那大学
  • ICMJE

查看更多

期刊国际标准号

期刊 h 指数

Flyer