抽象的

Simultaneous Estimation of Ofloxacin and Tinadazole by Reverse Phase High Performance Liquid Chromatography

S. Appala Raju, P. N. Sanjay Pai, Khaja Pasha and S. Humaira


An HPLC method for simultaneous estimation of ofloxacin and tinidazole was developed using SS wakosil II. C18, 250 x 4.6 mm, 5 μm column. With mobile phase composition of acetonitrile and phosphate buffer 3 : 1 (pH 5), flow rate of 1.0 mL/min and UV detection at 295 nm linearity was observed over concentration range of 10-50 μg/ mL for ofloxacin and 10-80 μg/ mL for tinidazole. The accuracy of the proposed method was determined by recovery studies and found to be 95-105% for ofloxacin and 101-103% for tinidazole, the proposed method was validated and results conformed with the ICH parameters.


索引于

  • 中国社会科学院
  • 谷歌学术
  • 打开 J 门
  • 中国知网(CNKI)
  • 引用因子
  • 宇宙IF
  • 米亚尔
  • 秘密搜索引擎实验室
  • 欧洲酒吧
  • 巴塞罗那大学
  • ICMJE

查看更多

期刊国际标准号

期刊 h 指数

Flyer