抽象的

Simultaneous RP-HPLC determination of gatifloxacin and ambroxol hydrochloride in pharmaceutical preparations

Manisha M.Baing, V.V.Vaidya, N.J.Rane, P.A.Champanerkar


A rapid and accurate reversed phase high performance liquid chromatographic method has been developed for the simultaneous determination of Gatifloxacin andAmbroxol hydrochloride. Ciprofloxacinwas used as internal standard. Chromatographic separation of the two drugs was performed on aBDSHypersilC18 column (150mm 4.6mm, 5m)with a 65:15:20 (v/v) mixture of 0.05Mpotassiumdihydrogen phosphate, acetonitrile, andmethanol (0.1%triethyl amine pH adjusted to 3.0 with orthophosphoric acid) at a flowrate of 1.0ml/min and detection at 220nm. The separationwas complete in less than 10 mins. The method was validated for linearity, accuracy, precision, limit of quantitation and robustness[2,3]. Linearity, accuracy and precision were found to be acceptable over the ranges of 120 - 280g mL-1 for Gatifloxacin and 18- 42gmL-1 forAmbroxol hydrochloride.


索引于

  • 中国社会科学院
  • 谷歌学术
  • 打开 J 门
  • 中国知网(CNKI)
  • 引用因子
  • 宇宙IF
  • 电子期刊图书馆
  • 研究期刊索引目录 (DRJI)
  • 秘密搜索引擎实验室
  • ICMJE

查看更多

期刊国际标准号

期刊 h 指数

Flyer