抽象的

Validated stability indicating RP-HPLC method for the determination of Cobicistat in bulk and pharmaceutical formulations

K.Sureshbabu, B.Koteswararao, C.Rambabu


A new validated RP-HPLC method was developed for the determination of Cobicistat in dosage form. The developed method produced high sensitivity, precision and accuracy. An isocratic C18 (Hypersil BDS, 150 mm x 4.6 mm, 5µ) column was used with mobile phase of composition acetonitrile : phosphate buffer (10 : 90 at pH 6.5) at a flow rate of 1.0 mL/min with UV detection at wavelength of 240 nm for Cobicistat. The retention time of the drug was 4.078 minutes. The developed method was validated for specificity, linearity, precision, accuracy and robustness as per ICH guidelines. Linearity was found in the range of 7.5 – 45.0 µg/ml. The percentage recoveries of the drug ranged from 99.23 – 99.97 %. Forced Degradation study was carried out by treating the sample under the acidic, alkaline, thermal and photo conditions. The results indicated that the any other impurity is not merging with the main peak. The proposed method could be used for routine analysis of Cobicistat in their dosage forms.


索引于

  • 中国社会科学院
  • 谷歌学术
  • 打开 J 门
  • 中国知网(CNKI)
  • 引用因子
  • 宇宙IF
  • 电子期刊图书馆
  • 研究期刊索引目录 (DRJI)
  • 秘密搜索引擎实验室
  • ICMJE

查看更多

期刊国际标准号

期刊 h 指数

Flyer